Specialists in operable walls & moveable partitions from Hufcor

Style Partitions     style partitions  
In partnership with Hufcor
Call me back at a time which is more convenient

Timber partitions - Timberfold

 

Timberfold

technical information


Timberfold partitions are Top Hung on a galvanised steel track with steel wheeled bearing carriers. Timberfold partitions provide Class '1' Surface Spread of Flame rating as standard read more...

Available in either Sidefold or Centrefold configuration with floor channel which must be recessed into a hardwood cill.

Technical Specification Information - Timberfold Partitions

Fire
Performance
Panel
weight
Kg/m²
Series
Ref./NBS
Specification
Max
height
mm
Nominal
panel
thickness
Configuration

Timberfold partitions

Flame spread rating class 1
Flame spread rating class 0*
21
(veneer)
23
(laminate)

TF44

3060 44mm Top Hung
with Floor Guide
Sidefold
or Centrefold
* Class 0 requires intumescent lacquer
Optional brush stripping and neoprene seals to enhance acoustic rating

Specifications:

  • Maximum opening width - no limit, use any number of same width floating units
  • Panel width 600 - 900mm
  • Class '1' Surface Spread of Flame rating

Standard construction consist of:

  • Solid core timber construction
  • Hardwood lipping to vertical edges
  • Constructional veneer to both faces
  • Galvanised steel track
  • Steel wheeled bearing carriers
  • Aluminium floor channel
  • Faces finished as required (Veneer, Laminate etc.)

Options:

  • Top and bottom - brush stripping to enhance acoustic rating
  • Vertical edges - Neoprene seal to rebated joints to enhance acoustic rating
  • Independent "floating" units for larger openings

Sidefold

Centrefold

Normally attached to the jamb post in continuous hinged unit to a maximum of five panels, projecting to one side of the opening. For wider openings, independent floating 4 or 6 panel units can be used. Units can be designed to park at one or both ends of the track in single stacks. Sidefold drawing

Normally consisting of an odd number of full-width panels plus one half-width panel, continuously hinged to the jamb, a maximum of five and a half panels. For larger openings, additional 3 or 5 panel "floating" units may be employed. Centrefold drawing

Timberfold Fire Performance
As standard Timberfold partitions offer Class '1' Surface spread of Flame as defined in paragraph A12(b) of Approved Document B, "Fire Safety, to the Building Regulations, 1991. Class '0' requires an intumescent lacquer to be applied to the partition.

Care should be taken that the subsequent site decoration does not compromise this rating. Where applied finishes other than standard are specified, advice should be sought from you local fire officer.

For Half-Hour and One-Hour fire resistance see Firefold partitions.

Warranty
All Hufcor products are guaranteed for two years against defective materials and workmanship

top

 
Web Design By